Originally posted by FavoriteMystaque:
I checked the schematic, the fuse 5 does feed the regulator and fogs, different than my 95 diagrams..




Ya, it seems very odd to me...i looked at the fog lamp schematic, and unless the schematic is wrong or i read it wrong, it seems like fuse 5 feeds the power to the fog relay, then when the relay closes, power from fuse 5 is routed to the fogs....there were no other fuses in that path....so that means if one of your fogs happens to short out for whatever reason, all of a sudden your alternator won't charge the battey? ...I didn't think they'd do it that way.


1998 Mystique LS: -2.5 Duratec ATX -Vibrant White -------------------- =Pics= =Info=