Hey guys,
I was trying to do my alternator since th ebattery light was on, while removing the coil pack i found this wire and have no idea what the deal is. Can someone identify this for and and let me know if this could cause a battery light to be on constantly? thanks


This wire was below the coil pack near a big wire harness

Last edited by TravisN1; 05/27/06 05:05 PM.
#1579443 05/27/06 06:20 PM
Joined: Mar 2002
Posts: 496
E
CEG\'er
Offline
CEG\'er
E
Joined: Mar 2002
Posts: 496

#1579444 05/27/06 10:43 PM
Joined: May 2000
Posts: 3,335
E
Hard-core CEG'er
Offline
Hard-core CEG'er
E
Joined: May 2000
Posts: 3,335
It is a broken Maxi fuse. With it being dead your alternator will not charge and the battery light will be forever on (until the battery dies). Last one I had die was fairly cheap, even from the dealer.


· Jon Miconi · Coming Soon! · 01 Cougar · 98 V70R
#1579445 05/28/06 03:42 AM
Joined: Jul 2005
Posts: 81
T
CEG\'er
OP Offline
CEG\'er
T
Joined: Jul 2005
Posts: 81
WHat causes this fuse to die? Do i need to be looking into something else or could the fuse have just gone bad randomly?

#1579446 05/28/06 04:03 AM
Joined: Jun 2005
Posts: 5,345
T
Addicted CEG\'er
Offline
Addicted CEG\'er
T
Joined: Jun 2005
Posts: 5,345
Originally posted by TravisN1:
.. could the fuse have just gone bad randomly?



Maybe, but more so the voltage regulator in the alternator is not working.

Charging system from Autozone.
http://www.autozone.com/servlet/UiBroker?ForwardPage=/az/cds/en_us/0900823d/80/1b/c2/fd/0900823d801bc2fd.jsp

Last edited by Tony2005; 05/28/06 04:08 AM.

"Always do the cheap and easy ones first." 1996 V6 ATX 96K miles
#1579447 05/29/06 02:06 AM
Joined: Jul 2005
Posts: 81
T
CEG\'er
OP Offline
CEG\'er
T
Joined: Jul 2005
Posts: 81
thanks for the info.
Do you think i should just replace the maxi-fuse and call it good or is my alternetor prob. toast too? The alternator is tough to get to and i don;t want to replace it if it is not needed. Could the maxi-fuse have blown from a sound system in the car? I had a system put in several months ago and only used it for like 6 weeks and blew out the sub, so it is all hooked up just sitting in the trunk. Anyway any thoguhts are helpful, i would like to minimize the time and money spent on this so why help is useful.

#1579448 05/29/06 02:10 AM
Joined: Jun 2005
Posts: 5,345
T
Addicted CEG\'er
Offline
Addicted CEG\'er
T
Joined: Jun 2005
Posts: 5,345
"Do you think i should just replace the maxi-fuse and call it good"
Yes for now. Then test alternator after charging the battery well.

Engine running. Voltage across battery terminals should be 14 to 14.5 volts.

"Could the maxi-fuse have blown from a sound system in the car?"
Maybe.


"Always do the cheap and easy ones first." 1996 V6 ATX 96K miles
#1579449 05/29/06 02:01 PM
Joined: Jul 2005
Posts: 81
T
CEG\'er
OP Offline
CEG\'er
T
Joined: Jul 2005
Posts: 81
Thanks Tony for your help. I've never had a big fuse like this go out before, but at least that happened rather then melting wires i guess

#1579450 06/05/06 12:19 PM
Joined: Dec 2003
Posts: 285
F
CEG\'er
Offline
CEG\'er
F
Joined: Dec 2003
Posts: 285
The only time I've ever had the maxi fuse go in these cars is from a bad alternator. You can install a new fuse and probably be alright for a short time, but a blown maxi fuse is a symptom of a problem and most likely the source is your alternator.