just want to know witch fan is the low speed fan so i can wire a switch to it so i can turn it on . because it does not work on its on. also im going to run the wire from the plug on the fan to the switch will that work or do i need to run it to a power wire first. or will the wire im tapping into have power already
Last edited by 98-contour-zetec; 01/29/06 03:58 PM.
|
|
|
|
Joined: Jul 2001
Posts: 7,100
Addicted CEG\'er
|
Addicted CEG\'er
Joined: Jul 2001
Posts: 7,100 |
Aren't Zetecs a "one-fan" car? duel speeds but one physical fan?
You're looking for the low-speed fan relay, is what I am assuming.
Oh.. and.. rather than just patching around a problem, you should probably attempt to determine WHY it isn't working.
'99 CSVT - Silver #222/276
In a constant state of blow-off euphoria.
Originally posted by Kremitthefrog: I like to wear dresses and use binoculars to watch grandmas across the street.
|
|
|
|
Joined: Mar 2005
Posts: 148
CEG\'er
|
OP
CEG\'er
Joined: Mar 2005
Posts: 148 |
no my 98 has two fans and one is low and one is high. i took the thing to the shop and thay had no clue as to why it was not coming on. thay could hook up there test stuff and make it come on by comand. thay said it could be anything. thay tested all sensors to not to mention i already replaced all of them with no change.so the next best thing is to bypass them and run it to a switch. got any idea. what to try other than the switch?
|
|
|
|
Joined: Sep 2002
Posts: 1,788
Hard-core CEG\'er
|
Hard-core CEG\'er
Joined: Sep 2002
Posts: 1,788 |
Seems I just pointed out recently to someone that the fans are wired in parallel.
That means, there is NO LOW SPEED FAN.
Both fans should operate at the same time and at the same speed.
Have you checked the low speed fan resistor and relay???
Steve
98 Contour SE Sport 2.5 Duratec ATX The wifey's car
89 Taurus SHO - 246K miles
94 SHO ATX - 190K
1997 F-150 5.4L ATX - The Workhorse 150K.
ANY THREAD WITH "OMG" or "WTF" ETC IN THE TITLE WILL BE IGNORED!
|
|
|
|
Joined: Oct 2004
Posts: 1,456
Hard-core CEG\'er
|
Hard-core CEG\'er
Joined: Oct 2004
Posts: 1,456 |
Try this link Fan circuit topic It will help you. There is a schematic on page 2.
|
|
|
|
Joined: May 2000
Posts: 21,197
I have no life
|
I have no life
Joined: May 2000
Posts: 21,197 |
From Terry, cooling fans are two, two-speed fans. If you look at the circuits when in low speed mode BOTH fans are fed Via the resistor and BOTH go at the slow speed. At high speed BOTH are fed without the resistor in the circuit. Neither is high or low. They are both high & low due to the wiring of the feed. Same goes for the early Zetec single fan...it is two speed due to the resistor in the circuit....to prove it out,if you wish,put a volt meter on each fan feed at low speed BOTH will show reduced voltage
via resistor...turn on the AC and BOTH will read battery volts...
-'96 SE MTX 3L
-'98 SVT 1,173 of 6,535
-'05 Mazda 6s, loaded, g/f's ride
-Need a 96-00 manual on CD? PM or email me
|
|
|
|
Joined: Mar 2005
Posts: 148
CEG\'er
|
OP
CEG\'er
Joined: Mar 2005
Posts: 148 |
ok i tested the 3and 5 pin on each relay and both fans work does that mean the pcm is not sending the signal to turn them on .
|
|
|
|
Joined: May 2000
Posts: 21,197
I have no life
|
I have no life
Joined: May 2000
Posts: 21,197 |
Might have bad ECT sensor. Pretty easy to swap out. About $15.
-'96 SE MTX 3L
-'98 SVT 1,173 of 6,535
-'05 Mazda 6s, loaded, g/f's ride
-Need a 96-00 manual on CD? PM or email me
|
|
|
|
Joined: Mar 2005
Posts: 148
CEG\'er
|
OP
CEG\'er
Joined: Mar 2005
Posts: 148 |
already replaced it 3 times. and the other one below it to .
|
|
|
|
Joined: May 2000
Posts: 21,197
I have no life
|
I have no life
Joined: May 2000
Posts: 21,197 |
-'96 SE MTX 3L
-'98 SVT 1,173 of 6,535
-'05 Mazda 6s, loaded, g/f's ride
-Need a 96-00 manual on CD? PM or email me
|
|
|
|
|
|