Posts: 15
My A/C decided to quit one hot morning. I began recharging the system and the high pressure valve leaked all the coolant out. I was told if the a/c fan wasn`t working at the time it would have caused the h/pressure valve to blow. The compressor did operate while coolant was in the system. Any clues would be appreciated, its going to be mighty hot in ATL soon.

#56772 03/27/02 04:29 AM
Joined: Oct 2000
Posts: 296
2
Member
Offline
Member
2
Joined: Oct 2000
Posts: 296
Don't know what year/powertrain you have. If it's a 95, like my 2, the hoses (made by BadYear) leak a little. I used the stopleak-conditioner for R134 and they have not leaked in over 2 years.
If the fan(s) are dead, or there is not enough air circulation, the compressor will cycle on/off real fast because of the high pressure in the system. There is a electrical pressure switch that turns the fans on high speed. I helped another CEGer with his wiring and switch problem and learned the system in the process. A week later, my radiator fans catch fire, didn't know it at first but I heard the compressor going on and off real fast and the Temp rising a little. By the time I pulled over smoke was pouring out. eek