Yes, it can wait but the engine will run on a limp mode when the CEL is on.

From TSB,

P0153 - HO2S Sensor Circuit Slow Response Bank 2 (Radiator side) Upper O2 sensor (HO2S-21) The HO2S monitor checks the HO2S sensor frequency and amplitude. If during testing, the frequency and amplitude were to fall below a calibrated limit, the code will set.

Electrical:
�· Shorted/open wiring
�· PCM

Induction System:
�· MAF sensor (On 4-cylinder engines, if P0133 is present, this could be caused by a MAF issue - on 6- and 8-cylinder engines, this could only be a MAF issue if P0133 and P0153 are both present)
�· Inlet air leaks (unmetered air)

Fuel Concerns:
�· Poor fuel quality

Base Engine:
�· Exhaust leaks (upstream or near HO2S)

HO2S Concerns:
�· Contaminated HO2S sensor (contamination from the use of silicone-based cleaners and sealants, leaded fuel, excessive oil consumption, etc.)
�· Deteriorating HO2S sensor

Edit. If you want to change the Bank 2 Upper O2 sensor;

On this 2-D picture, ignore the red box and arrow, the Bank 2 Upper is the sensor on the left of the pre-cat. The arrow is pointing to the Bank 2 pre-cat
Originally posted by chongo:




Last edited by Tony2005; 02/22/06 01:23 AM.

"Always do the cheap and easy ones first." 1996 V6 ATX 96K miles