#701004 07/23/03 04:52 PM
Joined: Jul 2002
Posts: 2,586
S
Hard-core CEG'er
OP Offline
Hard-core CEG'er
S
Joined: Jul 2002
Posts: 2,586
Anyone here working in this environment? I'm having problems with one of my servers and the IMA service stopping unexpectedly.

I check my event viewer for that server and get a event 7031.

I've checked the citrix KB to no avail. Anyone else here have had this problem?

thanks for any help


97 T-Red LX ATX pre98 CF SVT front,SVT rear/side skirts FSVT wheels Custom Front Ford Logo (body Colour) 35% tint all around with sun visor WP With Metal Impeller? Elky Grills CTA Intake CTA Custom Dual Exhaust
#701005 07/23/03 05:26 PM
Joined: Jun 2000
Posts: 1,710
C
Hard-core CEG\'er
Offline
Hard-core CEG\'er
C
Joined: Jun 2000
Posts: 1,710
I hate Citrix. I was at work until 1am last night working on setting up an environment. I have to set up a farm of 9 servers. Each with a maximum connection limit of 2 per server so when someone tries to connect to the 1st server and 2 othe rpoeple are connected, the 3rd guy would get bumped down to the next server. its a pain in the azz. I have not had the problem you are speaking of yet but if i run into it I will let you know.


- Tim
#701006 07/23/03 06:30 PM
Joined: Jul 2002
Posts: 2,586
S
Hard-core CEG'er
OP Offline
Hard-core CEG'er
S
Joined: Jul 2002
Posts: 2,586
its so annyoing.

we have a 3 server Farm here. With each one having a capacity of 50 users.

anyways, if you happen to be looking @ the users through the Metaframe software and notice that one of the servers is not showing its users. Check that servers IMA service and you will find that it has stopped. All you need to start that service again.

this is my problem...


97 T-Red LX ATX pre98 CF SVT front,SVT rear/side skirts FSVT wheels Custom Front Ford Logo (body Colour) 35% tint all around with sun visor WP With Metal Impeller? Elky Grills CTA Intake CTA Custom Dual Exhaust
#701007 07/25/03 03:06 AM
Joined: Jun 2000
Posts: 1,710
C
Hard-core CEG\'er
Offline
Hard-core CEG\'er
C
Joined: Jun 2000
Posts: 1,710
Well, here is my problem. Every time I try to lo on to any of the servers in the farm, it says this server is not accepting any connections at this time!!!!! ARG! What a useless piece of software! I have to go into work @ 6:30am tomorrow to fix it cause testing starts at 9! I had it all running fine then people started farting around with it and now its completely fugged. IDIOTS!


- Tim
#701008 07/25/03 03:50 PM
Joined: Jul 2000
Posts: 26
M
New CEG\'er
Offline
New CEG\'er
M
Joined: Jul 2000
Posts: 26
We have a 3 server farm here.. We also had problems with the IMA service dying on us. What it turned out to be was load balancing causing problems. If you have it set to advanced, you will have issues.. set it to basic and it should help. If it already set to basic, I cant help ya much.

We went through 3 months of constant server crashes and freezes untill we saw that, set it to basic all has been well ever since.

Hope this helps.


Jon - NJNECO - Simply Domestic 2000 Silver Frost Cougar v6 MTX Dyno Tested 173.6 whp - 161.2 wtq Visit www.mastamoon.com for Details!
#701009 07/25/03 05:37 PM
Joined: May 2000
Posts: 970
J
Veteran CEG\'er
Offline
Veteran CEG\'er
J
Joined: May 2000
Posts: 970
Ahhh, give me an X Server through SSH port forwarding anyday...


98 GL sport (V6 MTX) The Durable Duratec? - (DMD, Metal impeller WaterPump, Synth & Stinky in the tranny)
#701010 07/25/03 06:31 PM
Joined: Jul 2002
Posts: 2,586
S
Hard-core CEG'er
OP Offline
Hard-core CEG'er
S
Joined: Jul 2002
Posts: 2,586
could you go into more depth here? I'm a novice with Citrix.

Which server do I change the setting on? all three Meta's or just the main one?

as well, are we talking about the load evaluators?


97 T-Red LX ATX pre98 CF SVT front,SVT rear/side skirts FSVT wheels Custom Front Ford Logo (body Colour) 35% tint all around with sun visor WP With Metal Impeller? Elky Grills CTA Intake CTA Custom Dual Exhaust
#701011 07/25/03 06:43 PM
Joined: Jul 2000
Posts: 26
M
New CEG\'er
Offline
New CEG\'er
M
Joined: Jul 2000
Posts: 26
On the main app server, You do it through the CMC (citrix managment console).. go down to servers, right click, load manage servers. You should see a list of servers on the left hand side.. click add all, choose default from the box below that click apply.. the servers should jump to the left again and have a default under evaluators.

if they already have a default under evaluators you dont need to do this obviously.


Jon - NJNECO - Simply Domestic 2000 Silver Frost Cougar v6 MTX Dyno Tested 173.6 whp - 161.2 wtq Visit www.mastamoon.com for Details!
#701012 07/25/03 07:22 PM
Joined: Jul 2002
Posts: 2,586
S
Hard-core CEG'er
OP Offline
Hard-core CEG'er
S
Joined: Jul 2002
Posts: 2,586
nice I see that.

Thanks man I'll giver a try and I'll post a follow up later.

Thanks again!


97 T-Red LX ATX pre98 CF SVT front,SVT rear/side skirts FSVT wheels Custom Front Ford Logo (body Colour) 35% tint all around with sun visor WP With Metal Impeller? Elky Grills CTA Intake CTA Custom Dual Exhaust
#701013 07/29/03 06:26 PM
Joined: Jul 2000
Posts: 26
M
New CEG\'er
Offline
New CEG\'er
M
Joined: Jul 2000
Posts: 26
Any news? Hows it runnin?