Previous Thread
Next Thread
Print Thread
#683043 07/04/03 11:28 PM
Joined: Jun 2003
Posts: 504
C
Veteran CEG\'er
OP Offline
Veteran CEG\'er
C
Joined: Jun 2003
Posts: 504
im having a problem with my blower where every speed (except for high) is the same speed. i think it may be the fan switch..... can anyone confirm this? i have a 96' contour GL. thanx


"Here's a mirror, see your stupid face!"
#683044 07/07/03 01:56 AM
Joined: May 2003
Posts: 6
M
Newbie
Offline
Newbie
M
Joined: May 2003
Posts: 6

Sounds like yes you problem is a blower motor resistor pack!!!
He is located just down in the glove box !!








------------------

Contour 96 GL Red 2.0 Ztec
112k
Piooner DEH-P7400MP

#683045 07/07/03 05:33 AM
Joined: Sep 2000
Posts: 263
J
CEG\'er
Offline
CEG\'er
J
Joined: Sep 2000
Posts: 263

Being a 96 model you could get it changed out for free at the dealer. There is a recall on the resistor pack and wiring. Got mine done when the resitor pack blew.


------------------------------------------------- 1996SE sports package, Duratec MTX No mods yet. 80K Kilometers. ------------------------------------------------- Wife has 1996GL Zetec ATX.

Moderated by  horseydug_dup1, Ray_dup1 

Link Copied to Clipboard
Powered by UBB.threads™ PHP Forum Software 7.7.5