In the past 6 months today will be the second time that Ford has replaced my water pump. I know water pumps going out are common with the Contours but twice in the last 6 months. This is annoying. Anyone else have this problem?


1998.5 Contour SVT
****Mods****
KKM Intake/Custom Exhaust/Custom Spoiler/B&M Short Throw Shifter/Eibach Springs/and of course a stereo
****Future Mods****
I have plenty in mind.

All spelling mistakes, grammatical errors and stupid comments are intentional.

Check out my car
http://www.stlsp.com/freeborncontour.html
Let me know what you think
Joined: Dec 2001
Posts: 162
J
Member
Offline
Member
J
Joined: Dec 2001
Posts: 162
Has the tensioner been replaced? I recall that's gotta be replaced as well, think it's in a Ford Service TSB.


98 CSVT, basic mod's, my slowest car yet but still faster than the wife's Talon Tsi AWD. Not by much, though. Now if I could get the back wheels to do something....
Joined: Jul 2000
Posts: 860
J
Member
Offline
Member
J
Joined: Jul 2000
Posts: 860
Inside the water pump housing, there is a metal washer that directs the coolant flow. Fairly often, it seems, this works loose from the housing, and causes the water pump to fail, by rubbing/interfering with the impeller.
If they replaced the water pump and failed to notice this, it would cause a recurring problem such as you described.


-Jeff
-"The Crazy Canuck!!"
-"Rice": Anything that looks faster than it really is...

My Ride! http://members.sounddomain.com/sideoftheroad
Joined: Aug 2001
Posts: 135
M
Member
OP Offline
Member
M
Joined: Aug 2001
Posts: 135
The tensioner has been replaced. Thanks for the info about the metal washer coming loose. Anyone else have this same problem?


1998.5 Contour SVT
****Mods****
KKM Intake/Custom Exhaust/Custom Spoiler/B&M Short Throw Shifter/Eibach Springs/and of course a stereo
****Future Mods****
I have plenty in mind.

All spelling mistakes, grammatical errors and stupid comments are intentional.

Check out my car
http://www.stlsp.com/freeborncontour.html
Let me know what you think
Joined: Oct 2001
Posts: 291
D
Member
Offline
Member
D
Joined: Oct 2001
Posts: 291
first i have heard of the metal washer. could this be what is causing the multiple failures? exactly where is this metal washer and how can it be identified, replaced, or repaired? we need to know these things!!!!!!!!!

Joined: Mar 2001
Posts: 27
J
Junior Member
Offline
Junior Member
J
Joined: Mar 2001
Posts: 27
No, you're not the only one who's needed multiple water pump replacements. When my pump went out at ~60k it took the dealer 4 replacement pumps before they managed to keep one running (I'm now at 105k). None of the 1st 3 pumps lasted even 10k miles, and one only made it to 2k (average wa maybr 4-5k). I have no idea whether or not the dealer was properly cleaning out the washer or not. I got pretty pissed at the dealer, but eventually they managed to put a functional water pump in! All of the subsequent replacements after the 1st one was on their dime, of course, that's why I kept going back to them.


joel
'96 Contour SE ATX
Metallic champagne
Replaced headend radio
Added 6-cd changer
Standard high-beam bulbs used in the low-beam lights
ATX rebuilt at 102K
Otherwise stock.