Previous Thread
Next Thread
Print Thread
#1307615 06/16/05 04:37 AM
Joined: Jun 2005
Posts: 3
P
Puzzled Offline OP
Newbie
OP Offline
Newbie
P
Joined: Jun 2005
Posts: 3
I'm trying to figure this one out. A friend has a 95 Contour and it seems the turn signals and heater blower motor both stopped working at once. There is no power at the resistor for blower and none at terminals for flasher. However, the hazards work. The fuse for blower motor is hot. There is also no power at the blower switch...where is the blower relay and could this be a problem?
Does the multifunction switch have anything at all to do with blower circuit? I believe they are two totally different systems and should not be related. Probably a big coincidence...Maybe a circuit from the ignition switch...probably not....PLEASE HELP!!

Last edited by Puzzled; 06/16/05 04:41 AM.
#1307616 06/16/05 01:59 PM
Joined: Oct 2000
Posts: 463
M
CEG\'er
Offline
CEG\'er
M
Joined: Oct 2000
Posts: 463
Pull the blower fuse and connect an amp meter (20 amp range) in it�s place. Measure the current with the blower switch off then on (each position). Then replace the fuse, switch to volts and measure the voltage drop across the fuse in the blower off and on positions. Post your results.

Just a hint, the voltage across the fuse should be zero or almost zero. If the fuse is getting hot it indicates a voltage drop and current draw. The drop is likely from burnt or damaged fuse holder connectors (a common problem).
jeff




have you fixed your ford lately?
#1307617 06/16/05 02:00 PM
Joined: Jul 2002
Posts: 1,459
B
Hard-core CEG\'er
Offline
Hard-core CEG\'er
B
Joined: Jul 2002
Posts: 1,459
Last winter my blower switch stopped working (well, it worked occasionally), and my turn signals worked occasionally, but not often. The problem was with a fuse in the box under the dash. The same fuse (can't remember the number now) controls both functions. As it turned out, the fuse was okay, but the connection was loose. I took the fuse box apart and tightened the connection, and everything is fine now.



95 Contour Zetec, ATX (wrecked, sitting in the barn) 95 Mystique Zetec, MTX 2000 Taurus SEL 3.0L Duratec 1994 Crown Victoria LX 4.6 V8 1993 Chevy Silverado 4.3 V6
#1307618 06/18/05 07:56 AM
Joined: Jun 2005
Posts: 3
P
Puzzled Offline OP
Newbie
OP Offline
Newbie
P
Joined: Jun 2005
Posts: 3
Ok, I got it figured out finally...makes no sense but here it is. It seems that of all things the backup light switch was shorting and when the fuse blew the turn signals and heater blower motor stopped functioning. Disconnect the back up switch and problem was solved.Thanks for the input from both of you


Moderated by  horseydug_dup1, Ray_dup1 

Link Copied to Clipboard
Powered by UBB.threads™ PHP Forum Software 7.7.5